Super inverter
|
Continuous Power
|
300W
|
Surge power
|
750W ± 5% / 50ms
|
I standby
|
<= 100mA
|
Input
|
Main Battery
|
12VDC
|
Operating range
|
10.5 – 14.5VDC
|
Output
|
Voltage
|
220V AC ± 5%,
|
Frequency
|
50 Hz ± 1%
|
Efficiency
|
>= 87%
|
Waveform
|
Modified Sine
|
L.V.D
|
10,5V ± 0.2V
|
Manual reset
|
>= 11 V ± 0.2V
|
Protection
|
Overload
|
Inverter will shutdown
|
Short circuit
|
Low voltage disconnection
|
Reverse Battery’s pole
|
DC Fuse will break
|
DC Output
|
Power
|
12 V/ 20A max
|
I standby
|
<= 40mA
|
Protection
|
Overload, Short circuit (manual reset)
|
L.V.D at 10,5 V (Manual reset)
|
Solar Charge Controller
|
Solar Input
|
V< 20VDC, Imax =25A.
|
Battery
|
12VDC
|
Overcharge
|
14,5 V ± 0.2V
|
Recharge
|
13,2 V ± 0.2V
|
Led Indicator
|
Solar charging current (by meter)
|
Charging level Batt.1
|
Solar In, Overcharge Battery 2,
|
|
Dimension
|
(L x W x H)mm :270 x 190 x 100
|
Net weight (kg)
|
< 4kg
|
Guarantee period
|
12months
|
|
|
|